Browse by Category |
 |
| | |
| |
 |
Browse by Brand |
 |
| | |
| |  | |  |
| | | | | Get Realtime Shipping Rates from UPS | |  |
| | | | Description | | | | | | | The RHC Relative Humidity Controller is our most recent development in total humidity control. It is switchable between humidify and dehumidify. The RHC has a built- in onboard sensor which is accurate within +/- 5% with a set differential of 5%. Perfect for plant zone environments, reptile habitats, or just about any application requiring accurate response and control. Plug your humidity equipment into the 120 volt 3 prong outlet located on the bottom side of the unit.
The RHC(R) is similar to the RHC except it is designed with the capabilities of a 20 ft. remote sensor.
Both units operate equipment up to 15 amps at 120 volt.
The controller is to be connected by a standard 115 VAC NEMA 5-15 plug and socket. Units may have an optional plug in sensor or an integral sensor. The controller is enclosed in a corrosion proof plastic enclosure with pad printed operating information on the front. The enclosure is capable of being wall mounted. The controller has power and on indicators. The control has a switch to select humidify and dehumidify functions. The control will operate with accuracy over a useful range of 50 to 90% RH. Type of Control: The control may be switched between Open on Humidity Rise (Humidify) to Open on Humidity Fall (Dehumidify). The output is energized until the sensed humidity reaches the setpoint.
Setpoint: The adjustable setpoint is the off point for either mode. The setpoint is adjustable by a knob over a 50-90% RH min range. The differential between the on and off points is fixed at 5% RH.
Indicators: Input power is indicated by a red indicator. The output power is indicated by a green indicator.
Marking: The enclosure front panel is permanently marked by pad printing. The part number and date code (YYWW format) is marked on the back of the product.
Storage Temperature: -40 to 120 F. Operating Temperature: 40 to 110 F. Humidity: 5 to 95% RH, non condensing.
Enclosure sealing: NEMA 1 enclosure, not sealed to moisture. Control, and sensor, must be protected from chemical or water sprays. The enclosure is a plastic enclosure with UL94 V-0 flame rating.
Input Connection: Standard three wire NEMA 5-15P cordset. Input Power: 120 VAC, 15 A., 50/60 Hz. Output Connection: Integral NEMA 5-15R socket. Output Power: 120 VAC, 15 A., 1/2 Hp
External Sensor: External sensor wiring is low voltage isolated signals. Connections by standard RJ-12 crossover | | | | 100% Lowest Price Guaranteed! - Click here to know more |
| | | | | | | | |
|